home *** CD-ROM | disk | FTP | other *** search
/ Libris Britannia 4 / science library(b).zip / science library(b) / ENGINEER / 3923.ZIP / BTURES2.DAT < prev    next >
Text File  |  1991-11-04  |  4KB  |  127 lines

  1.  
  2.                                  Page 1 of 2
  3.  
  4.                          BTU Heating/Cooling Analysis
  5.  
  6.    08-29-1991
  7.  
  8.    A to Z Unlimited
  9.    901 Ferndale Blvd.
  10.    High Point, NC 27262
  11.  
  12. ****************************************************************************
  13. ****************************************************************************
  14.  
  15.    This analysis prepared especially for: John Doe
  16.  
  17.    John Doe
  18.    1234 Anywhere Ct.
  19.    High Point, NC 27260
  20.  
  21.                           *********** HEATING ***********
  22.  
  23.        The heating outside design temperature is  10 degrees fahrenheit.
  24.        The heating  inside design temperature is  72 degrees fahrenheit.
  25.        The heating  temperature  differential is  62 degrees fahrenheit.
  26.  
  27.    The heat loss for this building is      92,994 BTU's.
  28.  
  29.    The heating unit must handle   1,056 CFM's for proper heating.
  30.  
  31.    The above figures include outside ventilation of      20 CFM's.
  32.  
  33.    Any heating unit must be rated as close as possible to the heat loss
  34.    calculated in this study, but not less than that amount.
  35.  
  36.    The above CFM allows an 80 degrees rise in inlet to outlet air temperature.
  37.  
  38.  
  39.                           *********** COOLING ***********
  40.  
  41.        The cooling outside design temperature is  95 degrees fahrenheit.
  42.        The cooling  inside design temperature is  72 degrees fahrenheit.
  43.        The cooling  temperature  differential is  23 degrees fahrenheit.
  44.  
  45.    The heat gain for this building is      39,880 BTU's.
  46.  
  47.           This translates into       3.3 tons of cooling.
  48.  
  49.    The preferred cooling CFM is   1,196 CFM's for proper cooling.
  50.  
  51.                  For high humidity areas use       997 CFM's
  52.                  For normal humidity areas use   1,196 CFM's
  53.                  For low humidity areas use      1,395 CFM's
  54.  
  55.    The above figures include outside ventilation of      20 CFM's.
  56.  
  57.    Any cooling unit must be rated as close as possible to the heat gain
  58.    calculated in this study, but not less than that amount.
  59.  
  60. ****************************************************************************
  61.  
  62.                 Enchanted Tree Software - TROUBLESHOOTING Copy
  63.  
  64.                                  Page 2 of 2
  65.  
  66.                          BTU Heating/Cooling Analysis
  67.  
  68.    08-29-1991
  69.  
  70.    John Doe
  71.    1234 Anywhere Ct.
  72.    High Point, NC 27260
  73.  
  74. ****************************************************************************
  75. ****************************************************************************
  76.  
  77.  
  78.   *********** Structural analysis is based on the following data ***********
  79.  
  80.    Based on 1055 square feet, total exposed outside wall area.
  81.  
  82.        Wall construction is : Frame wall w/R-11. 
  83.        The wall has a heat transfer factor of .07 heating or cooling.
  84.  
  85.    Based on 2 doors, assuming 20 square feet per door.
  86.  
  87.        Door construction is : Solid wood, no storm.
  88.        The door has a heat transfer factor of .713 heating and .46 cooling.
  89.  
  90.    Based on 345 sq. ft. of window glass.
  91.  
  92.        All window construction is : Single glazed, plain, no storm. 
  93.        All windows have a heating factor of  1.505 
  94.  
  95.    There are 75 sq. ft. facing north, with a cooling factor of 30 
  96.    There are 0 sq. ft. facing northeast/west, with a cooling factor of 65 
  97.    There are 195 sq. ft. facing east/west, with a cooling factor of 90 
  98.    There are 0 sq. ft. facing southeast/west, with a cooling factor of 80 
  99.    There are 75 sq. ft. facing south, with a cooling factor of 50 
  100.  
  101.    Based on 1800 square feet total floor area.
  102.  
  103.    The foundation is : Over uncond. basement/enclosed crawl. 
  104.    The floor has a heat transfer factor of .312 heating and 0 cooling.
  105.  
  106.    The ceiling is : Ceiling under/vent. attic/uncond. room. 
  107.    Ceiling insulation is : R-11. 
  108.    The ceiling has a heat transfer factor of .088 heating and .083 cooling.
  109.  
  110.    This analysis is based on a moisture content of  20  grains.
  111.  
  112.  
  113.  
  114.  
  115.  
  116.  
  117.  
  118.  
  119.  
  120.  
  121.  
  122. ****************************************************************************
  123.    All heat gain factors above are for a 20 degree differential; all cal-
  124.    culated values are corrected for the applicable temperatures.
  125.  
  126.                 Enchanted Tree Software - TROUBLESHOOTING Copy
  127.